Introduction

The new Apex Pro IS personal sampling pump has been developed to provide sampling capabilities between 0.005 and 4 lpm. UL listing means that the pump may be used in any circumstance where intrinsic safety is an issue.

Applications

• Personal sampling for particulates in the breathing zone
• Designed to comply with EN1232, MDHS 14/3, NIOSH 0600 requirements
• Available as single kits
• Available in multiple 5 pack kits with a 5 way charger or 5 separate chargers
• Three button control coupled with a customized LCD lead to intuitive operation

Features

• Wide operating range: 0.8 to 4 lpm directly
• 5 to 750 ml/min with low flow adaptor
• Direct volumetric flow control
• Long term flow rate stability
• Infra-red com port for simplicity of downloads
• Up to 100 events may be stored in memory
• Drop in fast charging cradle
• Gas smpling bag outlet for grab sampling

 

Apex Pro 200
Apex Pro 200
The Casella Pump Manager software is available as an additional option (182091A) for use with the logging functions of the Apex IS Pro model and handles all the setup and downloading of the relevant pump run data for comprehensive reporting and archiving. Maintain a database of your measurements including the pump details and individual personal data. A drop in fast charger intelligently charges the Apex IS pumps and maintains them at peak power for a new measurement event.
Apex with Charger Base
Apex with Charger Base

Technical Information Intrinsically Safe Models Apex Pro IS

Flow range

Flow control accuracy
Flow performance
(Flow, max back pressure)
0.8 to 4.0 liters/minute standard flow rate
(5 to 750 milliliters/minute with optional Low Flow adaptor P109032))
<±3.0% for selected flow digitally controlled for utmost stability
1.0 liter/minute @ 32 in H2O (80 cm H2O)
2.0 liters/minute @ 22 in H2O (55 cm H2O)
3.5 liters/minute @ 6.4 in H2O (16 cm H2O)
Battery voltage and capacity 4.8 V NiMH / 1.7 Ah
Inlet pulsation ratio <10% using cyclone
@ 2.0 liters/minute approx. 3.0 in H2O
Satisfies NIOSH 0600 and EN 1232
Displayed values Real time flow rate, volume sampled, elapsed sample time, temperature, operating mode, program details
Pump MTBF (service interval) Typically >3000 hours
Operating temperature
Storage temperature
41 to 104 °F (5 to 40 °C)
14 to 122 ° F (-10 to 50 °C)
Charging technique
Typical charge time
External Power Supply Unit
(for drop in charging)
Drop in intelligent fast charger <1.5 hrs gives 8 hr run time
Fast charge with safety time out, takes 4.5 hours to fully charge pump
Casella 182261B single pump fast charger or 182226A 5 way pump fast charger keeps pump(s) always ready for use
Memory storage of data
Memory protection time
100 events saved in Apex Pro IS model
Approximately 20 minutes (with main battery removed)
Communications Infra red (via RS232 IR transducer) to Pump Manager software
Recorded values Start and stop times, duration flow rate, average sample temperature,
total volume sampled (in l or m3) error conditions such as blockages

Physical characteristics:
Size
Weight (inc. battery)


5.8 x 3.4 x 1.8 in (145 x 85 x 46 mm)
17.8 oz (500 gm)
Intrinsic Safety Approvals UL/CSA Class I, Divisions 1 & 2, Groups C & D; Class II, Divisions 1 & 2, Groups E, F & G; Class III hazardous locations
ATEX: 100-94/9/EC Directive EEx ia IIB T4, Equipment group II Category 1 G Gas, EN 50014, EN 50020, EN 1232 : 1997

Pump Performance

 
Typical filter pressure load in inches of H2O, typical battery life in hours
Filter type
1.0 liters/min
2.0 liters/min
3.0 liters/min
3.5 liters/min
4.0 liters/min
25 mm GFA 2.0 in, 51 hrs 3.0 in, 26 hrs 4.0 in, 15 hrs 5.0 in, 11 hrs 5.3 in, 2 hrs
25 mm 0.8 µm MCE 6.5 in, 31 hrs 11.0 in, 13 hrs 15.0 in, 1 hrs 17.0 in, N/A 19.0 in, N/A
25 mm 1.2 µm MCE 4.5 in, 42 hrs 11.0 in, 18 hrs 10.0 in, 11 hrs 11.8 in, <1hr 12.5 in, N/A
37 mm GFA

0.5 in, 58 hrs

1.5 in, 31 hrs 2.0 in, 17 hrs 2.5 in, 13 hrs 2.6 in, 12 hrs
5" backpressure
33 hrs
20 hrs
13 hrs
11 hrs
3 hrs


Ordering Information
Click on a part number to add that item to your Price Quote List.

182160B Apex Pro IS pump with NiMH Battery pack (less charger unit)
182160B/K1 Apex Pro IS pump including charger unit
182160B/K5 Apex Pro IS kit (5 pumps) including 5 way charger, s’ware and case
182160S/K5 5 Apex Pro IS pumps with 5 separate IS chargers, toolbox style carrying case, software & IR interface
182091A MS Windows based Pump Manager software with IR link and cable
182261B Single battery charger for Apex IS
182226A 5 way battery charger for Apex IS
182013C Replacement battery pack for Apex IS pump models
P109032 Low Flow Controller and Constant Pressure Unit

Copyright © 2006 by BGI / Modified: Friday, February 8, 2008

 

 

Lower Navigation Bar Ambient Monitoring Instruments Air Flow Calibrators BGI Cyclones Aerosol Generator and Collection Industrial Hygiene Industrial Air Quality Instruments Draeger Products Filter Media Calendar of Events Links Technical Information BGI History E-Mail BGI BGI Home Page

 