The GK 4.162 designed by BGI is the highest flow rate personal cyclone for respirable sampling. The sampler was developed under a contract supported by the National Institute for Occupational Safety and Health (NIOSH) and tested at the Health and Safety Laboratory (UK).
The design is a natural extension of the GK 2.69 Cyclone which was developed as a dual use cyclone for use in sampling Respirable and Thoracic dust fractions. It has become popular as a high flow rate Respirable sampler for Silica. At 4.2 lpm there were many investigators who nonetheless felt that this was not sufficient and something in the order of 8-10 lpm was necessary. A copy of the HSE Laboratory report is attached.
Regarding the correct flow rate, quoting directly from the report by Andrew Thorpe:
The GK4.162 cyclone sampler was found to conform to the respirable sampling convention defined in EN481 (1993) at flow rates between 8.5 & 9.5 l min-1. Between these flow rates, the measured D50 was between 2 - 8% of the target value of 4 μm and the sampler met the bias performance criteria (BPC) which states that _ 85% of all the calculated sampler biases should be within +/- 10% for size distributions with mass median aerodynamic diameters (MMAD)
between 1& 30 and geometric standard deviations (GSD) between 1.75 & 4.
Because of the high flow rates the BGI 400 Omni Personal sampler is recommended for this application.
Specifications |
| Height |
6.0 in. (15.2 cm) |
| Width |
2.0 in. (5.1 cm) |
| Depth |
2.0 in. (5.1 cm) |
| Weight |
8.9 oz. (253 g) |
| Length of Hose |
42 in. (1.06 m) |
| Construction Material |
Anodized Aluminum |
Ordering Information
Click on a part number to add that item to your Price Quote List. |
| GK4.162 |
Respirable/Thoracic Cyclone
(Does not include SKC Plastic Cassette) |
| 6012 |
Omni-400 High Flow 24 Hour Sampler |
| 225-8497 (SKC P/N) |
47 mm Plastic Cassette (Order from SKC) |
| 225-809 (SKC P/N) |
47 mm PVC Filters (Order from SKC) |
| 225-2903 (SKC P/N) |
47 mm Cellulose Pad (Order from SKC) |
Replacement Parts |
| 10254 |
"O" Ring for Cassette (6/pkg.) |
| GK6 |
"O" Ring for Grit Pot (6/pkg.) |
| 10255 |
"O" Ring for Cyclone Top (6/pkg.) |
| GK6A |
"O" Ring for Clean Out Plug (6/pkg.) |
| 10205 |
Alligator Clip w/ Screw and Washer |
1. A. Thorpe, 2011 Evaluation of the penetration characteristics of a high flow rate personal cyclone sampler for NIOSH. Health and Safety Laboratory Report ECM/2011/03 (CLICK HERE)
Disclaimer: Mention of any company or product name does not constitute endorsement by the National Institute for Occupational Safety and Health (NIOSH). In addition, citations to websites external to NIOSH do not constitute NIOSH endorsement of the sponsoring organization or their programs or products. Furthermore, NIOSH is neither responsible for the content of these web pages nor should the conclusions provided be construed to represent any agency determination or policy.
Copyright © 2012 by BGI / Modified: